Abstract
Several models available in the literature for modeling drug release were used to describe experimental data on indomethacin dissolution from ordered mesoporous silica MCM-41 and SBA-15. Sigmoid-shape behavior observed experimentally was successfully explained by a drug release model, which relies on the concentration-dependent drug release constant. Physical reasons for such dependence are discussed. This simple model containing just two adjustable parameters could be used for treat-ing dissolution data with sigmoid behavior
Original language | Undefined/Unknown |
---|---|
Pages (from-to) | 579–592 |
Journal | Chemical Engineering Communications |
Volume | 201 |
Issue number | 5 |
DOIs | |
Publication status | Published - 2014 |