Fast and sensitive coulometric signal transduction for ion-selective electrodes by utilizing a two-compartment cell

Tingting Han, Tao Song, Yu Bao, Wei Wang*, Ying He, Zhenbang Liu, Shiyu Gan*, Dongxue Han, Johan Bobacka, Li Niu

*Corresponding author for this work

Research output: Contribution to journalArticleScientificpeer-review

2 Citations (Scopus)

Abstract

Here, we propose a fast and sensitive coulometric signal transduction method for ion-selective electrodes (ISEs) by utilizing a two-compartment cell. A potassium ion-selective electrode (K+-ISE) was connected as reference electrode (RE) and placed in the sample compartment. A glassy carbon (GC) electrode coated with poly(3,4-ethylenedioxythiophene) (GC/PEDOT), or reduced graphene oxide (GC/RGO), was connected as working electrode (WE) and placed in the detection compartment together with a counter electrode (CE). The two compartments were connected with an Ag/AgCl wire. The measured cumulated charge was amplified by increasing the capacitance of the WE. The observed slope of the cumulated charge with respect to the change of the logarithm of the K+ ion activity was linearly proportional to the capacitance of the GC/PEDOT and GC/RGO, estimated from impedance spectra. Furthermore, the sensitivity of the coulometric signal transduction using a commercial K+-ISE with internal filling solution as RE and GC/RGO as WE allowed to decrease the response time while still being able to detect a 0.2% change in K+ concentration. The coulometric method utilizing a two-compartment cell was found to be feasible for the determination of K+ concentrations in serum. The advantage of this two-compartment approach, compared to the coulometric transduction described earlier, was that no current passed through the K+-ISE that was connected as RE. Therefore, current-induced polarization of the K+- ISE was avoided. Furthermore, since the GCE/PEDOT and GCE/RGO (used as WE) had a low impedance, the response time of the coulometric response decreased from minutes to seconds.
Original languageEnglish
Article number124623
Number of pages9
JournalTalanta
Volume262
DOIs
Publication statusPublished - 2023
MoE publication typeA1 Journal article-refereed

Keywords

  • Coulometric response
  • Amperometric response
  • Ion-selective electrodes as reference electrode
  • Two-compartment cell
  • Electrochemical impedance spectroscopy

Fingerprint

Dive into the research topics of 'Fast and sensitive coulometric signal transduction for ion-selective electrodes by utilizing a two-compartment cell'. Together they form a unique fingerprint.

Cite this