Reagentless impedimetric immunosensor for monitoring of methotrexate in human blood serum using multiwalled carbon nanotube@polypyrrole/polytyramine film electrode

Kayode Omotayo Adeniyi*, Blerina Osmanaj, Gopinathan Manavalan, Jyri Pekka Mikkola, Avni Berisha, Solomon Tesfalidet*

*Tämän työn vastaava kirjoittaja

Tutkimustuotos: LehtiartikkeliArtikkeliTieteellinenvertaisarvioitu

4 Sitaatiot (Scopus)
11 Lataukset (Pure)

Abstrakti

Ensuring effective monitoring of methotrexate (MTX) levels in the bloodstream of cancer patients undergoing high-dose methotrexate chemotherapy is crucial to prevent potentially harmful side effects. However, the absence of portable analytical devices suitable for point-of-care bedside monitoring has presented a significant obstacle to achieving real-time MTX monitoring. In this study, we developed an impedimetric immunosensor that doesn't require reagents for measuring MTX levels in undiluted human blood serum. This reagentless approach simplifies the assay process, enabling rapid and straightforward MTX quantification. The immunosensor transducer was fabricated by electrodepositing conductive network of porous multiwalled carbon nanotube@polypyrrole/polytyramine on screen-printed gold microchip electrode (SP–Au/MWCNT70@PPy-PTA). Polyclonal anti-MTX antibodies were immobilized on the film, acting as the immunorecognition element. Non-specific binding was prevented by blocking the transducer interface with denatured bovine serum albumin (dBSA) fibrils, resulting in SP-Au/MWCNT70@PPy-PTA/anti-MTXAb|dBSA film electrode. When MTX binds to the SP-Au/MWCNT70@PPy-PTA/anti-MTXAb|dBSA interface, the film conductance and electron transfer resistance changes. This conductivity attenuation allows for electrochemical impedimetric signal transduction without a redox-probe solution. The electrochemical impedance spectroscopy (EIS) results showed increased charge transfer resistance and phase angle as MTX concentrations increased. The SP-Au/MWCNT70@PPy-PTA/anti-MTXAb|dBSA demonstrated high sensitivity, with a linear response from 0.02 to 20.0 μM and a detection limit of 1.93 nM. The detection limit was 50 times lower than the intended safe level of MTX in human serum. The immunosensor exhibited minimal cross-reactivity with endogenous MTX analogs and serum proteins. The SP-Au/MWCNT70@PPy-PTA/anti-MTXAb|dBSA immunosensor presents a simple and rapid method for therapeutic drug monitoring compared to traditional immunoassay systems.

AlkuperäiskieliEnglanti
Artikkeli125316
Sivumäärä12
JulkaisuTalanta
Vuosikerta268
Numero1
DOI - pysyväislinkit
TilaJulkaistu - 1 helmik. 2024
OKM-julkaisutyyppiA1 Julkaistu artikkeli, soviteltu

Sormenjälki

Sukella tutkimusaiheisiin 'Reagentless impedimetric immunosensor for monitoring of methotrexate in human blood serum using multiwalled carbon nanotube@polypyrrole/polytyramine film electrode'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.

Viittausmuodot