Återgå till huvudnavigering Återgå till sök Gå direkt till huvudinnehållet

Improving the selective naked-eye detection of COVID-19 mediated by simultaneously using three different target oligonucleotides coated on plasmonic AuNPs/hexagonal Ag@AuNPs

  • Neda Hosseinpour Moghadam
  • , Rezvan Najafi*
  • , Ali Ghanbariasad*
  • , Amin Shiralizadeh Dezfuli
  • , Akram Jalali
  • *Korresponderande författare för detta arbete

Forskningsoutput: TidskriftsbidragArtikelVetenskapligPeer review

2 Citeringar (Scopus)

Sammanfattning

The localized surface plasmon resonance (LSPR) phenomenon provides a versatile property in biosensor technology. This uncommon feature was utilized to produce a homogeneous optical biosensor to detect COVID-19 by the naked-eye readout. In this work, we synthesized two types of plasmonic nanoparticles: (i) AuNPs and (ii) hexagonal core-shell nanoparticles-Au shell on AgNPs (Au@AgNPs). We report herein the development of two colorimetric biosensors employing the efficient targeting and the binding ability for three regions of the COVID-19 genome, that is, S-gene, N-gene and E-gene, at the same time. Two AuNPs and Ag@AuNPs individually coated with three different targets oligonucleotide sequence (TOs) (AuNPs-TOs-mix and Ag@AuNPs-TOs-mix) for simultaneous detection of S-gene, N-gene and E-gene of the COVID-19 virus, using the LSPR and naked-eye methods in the laboratory and biological samples. The target COVID-19 genome RNA detected using the AuNPs-TOs-mix and Ag@AuNPs-TOs-mix can achieve the same sensitivity. The detection ranges by the AuNPs-TOs-mix and Ag@AuNPs-TOs-mix are both sufficiently improved in equal amounts in comparison to any of the AuNPs-TOs and Ag@AuNPs-TOs. The sensitivity of the current COVID-19 biosensors were 94% and 96% based on the number of positive samples detected for AuNPs-TOs-mix and Ag@AuNPs-TOs-mix, respectively. Moreover, all the real-time PCR confirmed negative samples obtained the same results by the biosensor; accordingly, the specificity of this approach got to 100%. The current study reports a selective, reliable, reproducible and visual ‘naked-eye’ detection of COVID-19, devoid of the requirement of any sophisticated instrumental techniques. Communicated by Ramaswamy H. Sarma.

OriginalspråkEngelska
Sidor (från-till)14372-14381
Antal sidor10
TidskriftJournal of Biomolecular Structure and Dynamics
Volym41
Nummer23
DOI
StatusPublicerad - 2023
Externt publiceradJa
MoE-publikationstypA1 Tidskriftsartikel-refererad

Finansiering

This study was funded by Hamadan University of Medical Sciences under Grant number 9907295321. Not applicable.

Fingeravtryck

Fördjupa i forskningsämnen för ”Improving the selective naked-eye detection of COVID-19 mediated by simultaneously using three different target oligonucleotides coated on plasmonic AuNPs/hexagonal Ag@AuNPs”. Tillsammans bildar de ett unikt fingeravtryck.

Citera det här