Sammanfattning
Model biofuel ash of well-defined size and melting properties was fed into an entrained flow reactor (EFR) to simulate the deposition behaviour of commercially applied biofuel mixtures in large-scale boilers. The aim was to obtain consistent experimental data that can be used for validation of computational fluid dynamics (CFD)-based deposition models. The results showed that while up to 80 wt% of the feed was lost to the EFR wall, the composition of the model ash particles collected at the reactor exit did not change. When model ashes were fed into the reactor individually, the ash particles were found to be sticky when they contained more than 15 wt% molten phase. When model ashes were fed in mixtures with silica sand, it was found that only a small amount of sand particles was captured in the deposits; the majority rebounded upon impact. The presence of sand in the feed mixture reduced the deposit buildup by more than could be expected from linear interpolation between the model ash and the sand. The results suggested that sand, addition to model ash may prevent deposit buildup through erosion.
Originalspråk | Odefinierat/okänt |
---|---|
Sidor (från-till) | 1970–1978 |
Antal sidor | 9 |
Tidskrift | Fuel |
Volym | 85 |
Nummer | 14-15 |
DOI | |
Status | Publicerad - 2006 |
MoE-publikationstyp | A1 Tidskriftsartikel-refererad |
Nyckelord
- co-combustion
- deposition
- model biofuel ash