Alternative method to prevent thermal runaway in case of error on operating conditions continuous reactor

Lamiae Vernières-Hassimi, Sebastien Leveneur

    Forskningsoutput: TidskriftsbidragArtikelVetenskapligPeer review

    18 Citeringar (Scopus)

    Sammanfattning

    Thermal runaway was studied in a continuous tubular pilot reactor under steady-state regime. Different accident scenarii were conducted by making some errors on reactant concentrations and/or temperature feed. To prevent thermal runaway, control by direct contact by solvent injection was used at different reactor locations. This injection allowed controlling the maximum reaction temperature. A simplified analytical method to estimate the maximum reaction temperature along the reactor was used.

    Benefit of this control method was the diminution of computational time. Furthermore, by injecting solvent to control maximum reaction temperature, there is no need to shut down the unit. The control method was validated experimentally.

    OriginalspråkOdefinierat/okänt
    Sidor (från-till)365–373
    TidskriftProcess Safety and Environmental Protection
    Volym98
    DOI
    StatusPublicerad - 2015
    MoE-publikationstypA1 Tidskriftsartikel-refererad