The sticky temperature of recovery boiler fireside deposits

HN Tran, X Mao, Kuhn DCS, R Backman, Mikko Hupa

    Tutkimustuotos: Artikkeli kirjassa/raportissa/konferenssijulkaisussaKonferenssiartikkeliTieteellinenvertaisarvioitu

    Abstrakti

    The sticky temp. of carryover particles in recovery boilers is an important parameter in boiler design and operation.  A study was undertaken to re-​evaluate the effect of chem. compn. on the sticky temp. of carryover particles.  The results showed that the sticky temp. is strongly related to particle size and liq. content.  Particles with a typical size range of 150-​300 μm will become sticky if their liq. content exceeds 15​%.  Based on this information, a series of sticky temp. contour maps were constructed which can be used to predict the sticky temp. of any sulfide-​free carryover particle as a function of chloride, K, and carbonate content.
    AlkuperäiskieliEi tiedossa
    OtsikkoInternational Chemical Recovery Conference : changing recovery technology to meet the challenges of the pulp and paper industry
    Toimittajat NN
    Sivut15–20
    TilaJulkaistu - 2001
    OKM-julkaisutyyppiA4 Artikkeli konferenssijulkaisuussa
    Tapahtumaconference; 2001-06-11; 2001-06-14 - Château Whistler Resort, Whistler, British Columbia, Canada
    Kesto: 11 kesäk. 200114 kesäk. 2001

    Konferenssi

    Konferenssiconference; 2001-06-11; 2001-06-14
    Ajanjakso11/06/0114/06/01

    Viittausmuodot