TY - JOUR
T1 - The effect of fibrin sealant on bioactive glass S53P4 particles – pH impact and dissolution characteristics in vitro
AU - Sarin, Jussi
AU - Björkvik, Leena
AU - Hiltunen, Markus
AU - Hupa, Leena
AU - Pulkkinen, Jaakko
AU - Vallittu, Pekka K.
N1 - ook
PY - 2016
Y1 - 2016
N2 - Fibrin glue, a two-component tissue adhesive, has a range of clinical indications. Bioactive glass (BG) S53P4 has been approved for clinical use in several craniomaxillofacial and orthopedic applications. Although sometimes used simultaneously, there is no data available regarding the possible interaction of these two biocompatible substances. In this in vitro study, using a BG particle concentration of 4 mg/ml, a 0.4 unit pH increment (p < 0.001) was observed in simulated body fluid (SBF) after a 7-day incubation period. The addition of fibrin glue (0.13 g, SD 0.04; or 3.7 mg/ml) on top of the BG particles raised further the pH by 0.5 units (p < 0.001). The difference between these groups was statistically significant (p = 0.008). With a BG concentration of 25 mg/ml and a fibrin glue concentration of 18 mg/ml during a 14-day incubation period, a pH increment of 0.6 units and SBF ion concentration change of Ca, K, Mg, Na, P and Si ions was seen. Moreover, a penetration depth between 4 and 6 mm was observed when fibrin glue was applied on top of a bed of BG particles. Conclusions: Fibrin glue is not likely to have a distracting effect on BG-induced pH increase of the SBF although it might delay early BG surface reactions based on ion concentration measurements. Fibrin glue penetrated to the interparticle space to some extent, binding the particles together for easy clinical use of BG.
AB - Fibrin glue, a two-component tissue adhesive, has a range of clinical indications. Bioactive glass (BG) S53P4 has been approved for clinical use in several craniomaxillofacial and orthopedic applications. Although sometimes used simultaneously, there is no data available regarding the possible interaction of these two biocompatible substances. In this in vitro study, using a BG particle concentration of 4 mg/ml, a 0.4 unit pH increment (p < 0.001) was observed in simulated body fluid (SBF) after a 7-day incubation period. The addition of fibrin glue (0.13 g, SD 0.04; or 3.7 mg/ml) on top of the BG particles raised further the pH by 0.5 units (p < 0.001). The difference between these groups was statistically significant (p = 0.008). With a BG concentration of 25 mg/ml and a fibrin glue concentration of 18 mg/ml during a 14-day incubation period, a pH increment of 0.6 units and SBF ion concentration change of Ca, K, Mg, Na, P and Si ions was seen. Moreover, a penetration depth between 4 and 6 mm was observed when fibrin glue was applied on top of a bed of BG particles. Conclusions: Fibrin glue is not likely to have a distracting effect on BG-induced pH increase of the SBF although it might delay early BG surface reactions based on ion concentration measurements. Fibrin glue penetrated to the interparticle space to some extent, binding the particles together for easy clinical use of BG.
U2 - 10.1016/j.jsamd.2016.10.006
DO - 10.1016/j.jsamd.2016.10.006
M3 - Artikel
SN - 2468-2284
VL - 1
SP - 482
EP - 487
JO - Journal of Science: Advanced Materials and Devices
JF - Journal of Science: Advanced Materials and Devices
IS - 4
ER -