Siirry päänavigointiin Siirry hakuun Siirry pääsisältöön

Single Molecule with a Large Transistor – SiMoT cytokine IL-6 Detection Benchmarked against a Chemiluminescent Ultrasensitive Immunoassay Array

  • Cecilia Scandurra
  • , Kim Björkström
  • , Lucia Sarcina
  • , Anna Imbriano
  • , Cinzia Di Franco
  • , Ronald Österbacka
  • , Paolo Bolella
  • , Gaetano Scamarcio
  • , Luisa Torsi*
  • , Eleonora Macchia*
  • *Tämän työn vastaava kirjoittaja

Tutkimustuotos: LehtiartikkeliArtikkeliTieteellinenvertaisarvioitu

15 Sitaatiot (Scopus)
256 Lataukset (Pure)

Abstrakti

Early diagnosis and efficient treatments of oncological, neurological, inflammatory, and infectious diseases rely more and more on ultrasensitive detection of protein markers; the ultimate limit is a reliable immunoassay capable of single-protein detection. Among protein biomarkers, cytokines play a key role in clinical diagnosis as they are involved in developing many complex diseases and disorders, such as chronic inflammatory diseases including metabolic syndrome, neurodegenerative diseases, and cardiovascular diseases, along with autoimmune diseases and cancer. Herein, the improvement of a Single Molecule with Transistor (SiMoT) is reported based on an electrolyte-gated organic field-effect transistor applied for the detection of cytokine IL-6 in blood serum, reaching a limit-of-detection (LOD) of 1 ± 1 protein in a sample of 0.1 mL. The analytical performance levels are benchmarked against the Simoa Planar Array SP-X technology, a benchtop chemiluminescent array. After comprehensive optimization, Simoa SP-X by using a multivariate experimental design approach exhibits a LOD 103 higher than SiMoT. The proposed SiMoT electronic assay is label-free, fast (30 min), and selective, paving the way for an ultra-sensitive point-of-care immunoassay platform enabling pre-symptomatic disease diagnosis.

AlkuperäiskieliEnglanti
Artikkeli2201910
JulkaisuAdvanced Materials Technologies
Vuosikerta8
Numero11
DOI - pysyväislinkit
TilaJulkaistu - 9 kesäk. 2023
OKM-julkaisutyyppiA1 Julkaistu artikkeli, soviteltu

Rahoitus

H2020 – Electronic Smart Systems – SiMBiT: Single‐molecule bio‐electronic smart system array for clinical testing (Grant agreement ID: 824946), NoOne‐A binary sensor with a single‐molecule digit to discriminate biofluids enclosing zero or at least one biomarker, ERC Stg2021, GA:101040383, Biosensori analitici usa‐e getta a base di transistori organici auto‐alimentati per la rivelazione di biomarcatori proteomici alla singola molecola per la diagnostica decentrata dell'HIV (6CDD3786); Research for Innovation REFIN—Regione Puglia POR PUGLIA FESR‐FSE 2014/2020, PMGB—Sviluppo di piattaforme meccatroniche, genomiche e bioinformatiche per l'oncologia di precisione—ARS01_01195‐PON “RICERCA E INNOVAZIONE” 2014–2020, Åbo Akademi University CoE “Bioelectronic activation of cell functions”, Svenska Tekniska Vetenskapsakademien i Finland, and CSGI are acknowledged for partial financial support.

YK:n kestävän kehityksen tavoitteet

Tämä tuotos edistää seuraavia kestävän kehityksen tavoitteita:

  1. SDG 3 – Hyvä terveys ja hyvinvointi
    SDG 3 – Hyvä terveys ja hyvinvointi

Sormenjälki

Sukella tutkimusaiheisiin 'Single Molecule with a Large Transistor – SiMoT cytokine IL-6 Detection Benchmarked against a Chemiluminescent Ultrasensitive Immunoassay Array'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.

Viittausmuodot