Pros and cons of using resazurin staining for quantification of viable Staphylococcus aureus biofilms in a screening assay

  • ME Sandberg
  • , D Schellmann
  • , G Brunhofer
  • , T Erker
  • , I Busygin
  • , Reko Leino
  • , PM Vuorela
  • , A Fallarero

    Tutkimustuotos: LehtiartikkeliArtikkeliTieteellinenvertaisarvioitu

    85 Sitaatiot (Scopus)

    Abstrakti

    Staining of Staphylococcus aureus biofilms with 20 mu M resazurin during 20 min was shown to provide a good screening assay in 96-well micro titer plates. However, data quality was found to be dependent on the staining duration and biofilm concentration. Also, the inadequacy of using resazurin calibration curves with planktonic cells to estimate S. aureus biofilm concentrations was demonstrated. (C) 2009 Elsevier B.V. All rights reserved.
    AlkuperäiskieliEi tiedossa
    Sivut104–106
    Sivumäärä3
    JulkaisuJournal of Microbiological Methods
    Vuosikerta78
    Numero1
    DOI - pysyväislinkit
    TilaJulkaistu - 2009
    OKM-julkaisutyyppiA1 Julkaistu artikkeli, soviteltu

    Keywords

    • Biofilms
    • Resazurin
    • Screening
    • Staphylococcus aureus