Fast and sensitive coulometric signal transduction for ion-selective electrodes by utilizing a two-compartment cell

  • Tingting Han
  • , Tao Song
  • , Yu Bao
  • , Wei Wang*
  • , Ying He
  • , Zhenbang Liu
  • , Shiyu Gan*
  • , Dongxue Han
  • , Johan Bobacka
  • , Li Niu
  • *Tämän työn vastaava kirjoittaja

Tutkimustuotos: LehtiartikkeliArtikkeliTieteellinenvertaisarvioitu

10 Sitaatiot (Scopus)
19 Lataukset (Pure)

Abstrakti

Here, we propose a fast and sensitive coulometric signal transduction method for ion-selective electrodes (ISEs) by utilizing a two-compartment cell. A potassium ion-selective electrode (K+-ISE) was connected as reference electrode (RE) and placed in the sample compartment. A glassy carbon (GC) electrode coated with poly(3,4-ethylenedioxythiophene) (GC/PEDOT), or reduced graphene oxide (GC/RGO), was connected as working electrode (WE) and placed in the detection compartment together with a counter electrode (CE). The two compartments were connected with an Ag/AgCl wire. The measured cumulated charge was amplified by increasing the capacitance of the WE. The observed slope of the cumulated charge with respect to the change of the logarithm of the K+ ion activity was linearly proportional to the capacitance of the GC/PEDOT and GC/RGO, estimated from impedance spectra. Furthermore, the sensitivity of the coulometric signal transduction using a commercial K+-ISE with internal filling solution as RE and GC/RGO as WE allowed to decrease the response time while still being able to detect a 0.2% change in K+ concentration. The coulometric method utilizing a two-compartment cell was found to be feasible for the determination of K+ concentrations in serum. The advantage of this two-compartment approach, compared to the coulometric transduction described earlier, was that no current passed through the K+-ISE that was connected as RE. Therefore, current-induced polarization of the K+- ISE was avoided. Furthermore, since the GCE/PEDOT and GCE/RGO (used as WE) had a low impedance, the response time of the coulometric response decreased from minutes to seconds.
AlkuperäiskieliEnglanti
Artikkeli124623
Sivumäärä9
JulkaisuTalanta
Vuosikerta262
DOI - pysyväislinkit
TilaJulkaistu - 1 syysk. 2023
OKM-julkaisutyyppiA1 Julkaistu artikkeli, soviteltu

Rahoitus

We are grateful to the National Natural Science Foundation of China (22227804, 22172040, 22174027 and 22204026), the Project Funded by China Postdoctoral Foundation (2022M710859), the Department of Science and Techniques of Guangdong Province (2021A1515010180), Guangzhou Municipal Science and Technology Bureau (202201000002) for their financial support of this work. Johan Bobacka acknowledges financial support from the Academy of Finland (project no. 317829).

Sormenjälki

Sukella tutkimusaiheisiin 'Fast and sensitive coulometric signal transduction for ion-selective electrodes by utilizing a two-compartment cell'. Ne muodostavat yhdessä ainutlaatuisen sormenjäljen.

Viittausmuodot