Dissolution patterns of biocompatible glasses in 2-amino-2-hydroxymethyl-propane-1,3-diol (Tris) buffer

Susanne Fagerlund, Leena Hupa, Mikko Hupa

    Tutkimustuotos: LehtiartikkeliArtikkeliTieteellinenvertaisarvioitu

    65 Sitaatiot (Scopus)

    Abstrakti

    A continuous flow measurement system with sensitive on-line ion analysis has been applied to study the initial dissolution behaviour of biocompatible glasses in Tris. Altogether 16 glasses with widely varying compositions were studied. The measurement system allowed for quantitative determination of the time-dependent rates of dissolution of sodium, potassium, calcium, magnesium, silicon and phosphorus during the first 10-15 min in contact with Tris solution. The dissolution rates of the different ions showed significant glass to glass variations, but all glasses studied showed one of four distinct dissolution patterns. The ion dissolution rates after an exposure of 1000 s, expressed as the normalized surface-specific mass loss rates, were compared with the in vitro and in vivo reactivity of the glasses as predicted by models in the literature. The results showed a clear correlation between the dissolution rates of the glasses in Tris and their reactivity as measured by other different methods. Consequently, the measured short-term dissolution patterns could be used to determine which glasses are suitable as bioactive, biodegradable, or inert biomaterials for medical devices.
    AlkuperäiskieliEi tiedossa
    Sivut5400–5410
    Sivumäärä11
    JulkaisuActa Biomaterialia
    Vuosikerta9
    Numero2
    DOI - pysyväislinkit
    TilaJulkaistu - 2013
    OKM-julkaisutyyppiA1 Julkaistu artikkeli, soviteltu

    Keywords

    • Biocompatible glass
    • Dissolution profile
    • Inductively coupled plasma
    • Ion release
    • Tris buffer

    Viittausmuodot