    Abstrakti

    The objective of this work is to evaluate and compare the effectiveness of input excitation signal design methods considering gain directions for the case of ill-conditioned multi-input multi output (MIMO) systems. For this purpose, a four inputs-four outputs (4 × 4) stripper section of distillation column is considered. Different plant friendly indices (such as, crest factor, PIPS) and fit percentage were used to quantify effectiveness of different input excitation signal design methods. Subsequently the quality of these methods and thus the quality of associated input excitation is evaluated through cross validation analysis.
    AlkuperäiskieliEi tiedossa
    Otsikko6th International Symposium on Communications, Control and Signal Processing (ISCCSP)
    ToimittajatConference Committee
    KustantajaIEEE
    Sivut368–371
    ISBN (painettu)978-1-4799-2890-3
    DOI - pysyväislinkit
    TilaJulkaistu - 2014
    OKM-julkaisutyyppiA4 Artikkeli konferenssijulkaisuussa
    Tapahtumaconference; 2014-05-21; 2014-05-23 - Athens
    Kesto: 21 toukok. 201423 toukok. 2014

    Konferenssi

    Konferenssiconference; 2014-05-21; 2014-05-23
    Ajanjakso21/05/1423/05/14