Alternative method to prevent thermal runaway in case of error on operating conditions continuous reactor

Lamiae Vernières-Hassimi, Sebastien Leveneur

    Tutkimustuotos: LehtiartikkeliArtikkeliTieteellinenvertaisarvioitu

    18 Sitaatiot (Scopus)

    Abstrakti

    Thermal runaway was studied in a continuous tubular pilot reactor under steady-state regime. Different accident scenarii were conducted by making some errors on reactant concentrations and/or temperature feed. To prevent thermal runaway, control by direct contact by solvent injection was used at different reactor locations. This injection allowed controlling the maximum reaction temperature. A simplified analytical method to estimate the maximum reaction temperature along the reactor was used.

    Benefit of this control method was the diminution of computational time. Furthermore, by injecting solvent to control maximum reaction temperature, there is no need to shut down the unit. The control method was validated experimentally.

    AlkuperäiskieliEi tiedossa
    Sivut365–373
    JulkaisuProcess Safety and Environmental Protection
    Vuosikerta98
    DOI - pysyväislinkit
    TilaJulkaistu - 2015
    OKM-julkaisutyyppiA1 Julkaistu artikkeli, soviteltu

    Viittausmuodot