Abstract
The sticky temperature of carryover Particles in kraft recovery boilers is an important parameter in boiler design and operation. Results of a collaborative study show that the sticky temperature depends strongly on particle size and liquid content. A series of sticky temperature contour maps has been constructed, which call be used to predict the sticky temperature of all sulphide-free carryover particle as a function of chloride, potassium and carbonate content.
| Original language | Undefined/Unknown |
|---|---|
| Pages (from-to) | 29–33 |
| Number of pages | 5 |
| Journal | Pulp & Paper Canada |
| Volume | 103 |
| Issue number | 9 |
| Publication status | Published - 2002 |
| MoE publication type | A1 Journal article-refereed |
Keywords
- deposits
- entrainment
- moisture content
- particle size
- particles
- recovery furnaces
- stickiness
- temperature