The sticky temperature of recovery boiler fireside deposits

HN Tran, X Mao, Kuhn DCS, R Backman, Mikko Hupa

    Research output: Contribution to journalArticleScientificpeer-review

    41 Citations (Scopus)

    Abstract

    The sticky temperature of carryover Particles in kraft recovery boilers is an important parameter in boiler design and operation. Results of a collaborative study show that the sticky temperature depends strongly on particle size and liquid content. A series of sticky temperature contour maps has been constructed, which call be used to predict the sticky temperature of all sulphide-free carryover particle as a function of chloride, potassium and carbonate content.
    Original languageUndefined/Unknown
    Pages (from-to)29–33
    Number of pages5
    JournalPulp & Paper Canada
    Volume103
    Issue number9
    Publication statusPublished - 2002
    MoE publication typeA1 Journal article-refereed

    Keywords

    • deposits
    • entrainment
    • moisture content
    • particle size
    • particles
    • recovery furnaces
    • stickiness
    • temperature