Abstract
Several models available in the literature for modeling drug release were used to describe experimental data on indomethacin dissolution from ordered mesoporous silica MCM-41 and SBA-15. Sigmoid-shape behavior observed experimentally was successfully explained by a drug release model, which relies on the concentration-dependent drug release constant. Physical reasons for such dependence are discussed. This simple model containing just two adjustable parameters could be used for treat-ing dissolution data with sigmoid behavior
| Original language | Undefined/Unknown |
|---|---|
| Pages (from-to) | 579–592 |
| Journal | Chemical Engineering Communications |
| Volume | 201 |
| Issue number | 5 |
| DOIs | |
| Publication status | Published - 2014 |
| MoE publication type | A1 Journal article-refereed |