Abstract
Printed potentiometric sensors require reliable solid contacts to provide stable and reproducible ion-selective electrodes. However, hampering fabrications and unfavorable maintenance often hinder their breakthrough on a commercial scale. Herein, we develop a solid-contact calcium-selective screen-printed electrode harnessing straightforward manufacturing based on the combination of carbon black (CB) and poly(3,4-ethylene dioxythiophene) doped with poly(sodium 4-styrenesulfonate) (PEDOT:PSS) as an ion-to-electron transducer. Drop-casting was used to simply deposit the CB layer, while PEDOT:PSS was rapidly electropolymerized (71 s) onto the working electrode to deliver affordable manufacturing of the printed electrode while ensuring valid potentiometric performance. Subsequently, the ion-selective membrane (ISM) and the polyvinyl butyral (PVB)-based reference membrane were, respectively, drop-cast onto the working electrode and reference electrode (RE). Upon the optimization of solid-contact layers, the solid-contact Ca2+-ISEs were investigated by evaluating their potentiometric performance versus a conventional RE. CB/PEDOT:PSS-modified screen-printed electrodes demonstrated a low-frequency capacitance of 55 mu F, and an outstanding standard potential interelectrode reproducibility (+/- 1 mV). The combination of both types of ion-to-electron transducers provided calcium detection in the linear range 10(-1)-10(-7) M with a Nernstian sensitivity (28.3 +/- 0.3 mV/decade), ensured over 28 days under dry storage. Furthermore, the absence of the water layer effect was also demonstrated. Lastly, the fully printed platform was assembled to achieve a miniaturized and easily field-deployable potentiometric device, consisting of CB/PEDOT:PSS/ISM configuration and PVB-based reference membrane on the working electrode and the RE, respectively. The resulted all-solid-state sensor revealed a Nernstian sensitivity with a 29.0 +/- 0.5 mV/decade slope and a stable signal up to 72 h (drift = -0.2 mV/h). Analysis carried out using commercially available bottled water also demonstrated the sensor successful performance in the determination of calcium ion in real samples.
| Original language | English |
|---|---|
| Pages (from-to) | 7820-7831 |
| Number of pages | 12 |
| Journal | ACS Sensors |
| Volume | 10 |
| Issue number | 10 |
| DOIs | |
| Publication status | Published - 24 Oct 2025 |
| MoE publication type | A1 Journal article-refereed |
Keywords
- Nernstian
- PEDOT:PSS
- PVB-based
- Calcium
- Electrode
- Ion-selective
- Ion-to-electron
- Potentiometric
- Screen-printed
- Sensor
- Solid-contact
Fingerprint
Dive into the research topics of 'Carbon Black and PEDOT:PSS in a Synergistic Solid Contact for Reliable Printed Potentiometric Sensors'. Together they form a unique fingerprint.Equipment
-
Åbo Akademi Functional Printing Center
Toivakka, M. (PI), Rosenholm, J. (PI), Anttu, N. (PI), Bobacka, J. (PI), Huynh, T. P. (PI), Peltonen, J. (PI), Wang, X. (PI), Wilen, C.-E. (PI), Xu, C. (PI), Zhang, H. (PI) & Österbacka, R. (PI)
Faculty of Science and EngineeringFacility/equipment: Facility