Alternative method to prevent thermal runaway in case of error on operating conditions continuous reactor

A1 Journal article (refereed)


Internal Authors/Editors


Publication Details

List of Authors: Lamiae Vernières-Hassimi, Sébastien Leveneur
Publication year: 2015
Journal: Process Safety and Environmental Protection
Volume number: 98
Start page: 365
End page: 373
eISSN: 1876-4800


Abstract

Thermal runaway was studied in a continuous tubular pilot reactor under steady-state regime. Different accident scenarii were conducted by making some errors on reactant concentrations and/or temperature feed. To prevent thermal runaway, control by direct contact by solvent injection was used at different reactor locations. This injection allowed controlling the maximum reaction temperature. A simplified analytical method to estimate the maximum reaction temperature along the reactor was used.

Benefit of this control method was the diminution of computational time. Furthermore, by injecting solvent to control maximum reaction temperature, there is no need to shut down the unit. The control method was validated experimentally.


Last updated on 2019-08-12 at 03:33